15 tons Bitzer
Purchase Enquiry:Mr. Zhong18565860589
Mr. Mo13631682431
Tube ice characteristics:
The tube ice is a relatively regular hollow cylindrical shape. The outer diameter is divided into three specifications of 22, 29, 35mm, and the height ranges from 25-60mm. The diameter of the inner hole in the middle can be adjusted according to the time of ice making, generally the diameter is 2-8mm between. The ice cube is hard, transparent and beautiful, not easy to melt, good air permeability, and long storage period. The shape is beautiful, and it is not only practical but also ornamental in the chilled food. Tube ice is mostly edible tube ice, which is mainly used for beverage cooling, food preservation, fishery preservation, laboratory and medical applications.
Product display:
<
Application scenarios:
Model Parameter category |
IT3T-R2/R4W |
IT5T-R2/4W |
IT10T-R2/4W |
Power Specifications |
3P/380/50HZ |
3P/380/50HZ |
3P/380/50HZ |
Compressor model |
4NES-12 |
4HE-18 |
6FE-50 |
Standard ice production |
3t/24h |
5t/24h |
10t/24h |
Standard pipe diameter |
φ29 |
φ29 |
φ29 |
Cooling capacity (kW) |
21.5 |
34.8 |
78 |
Evaporation temperature (℃) |
-12 |
-12 |
-12 |
Condensing temperature (℃) |
40 |
40 |
40 |
Total input power (kW) |
10.2 |
17 |
35 |
Compressor input power (kW) |
7.3 |
13.2 |
27.6 |
Input power of ice cutting reducer (kW) |
0.37 |
0.75 |
0.75 |
Input power of ice pump (kW) |
0.55 |
1.1 |
1.5 |
Cooling water pump |
YLGb50-18 |
YLGb65-20 |
YLGb80-20 |
Condenser water pump input power (kW) |
1.5 |
1.5 |
4 |
Cooling tower model |
CT-15 |
CT-25 |
CT-50 |
Cooling tower fan input power (kW) |
0.37 |
0.75 |
1.5 |
Water pressure requirements |
0.1Mpa-0.5Mpa |
0.1Mpa-0.5Mpa |
0.1Mpa-0.5Mpa |
The refrigerant |
R22/R404A |
R22/R404A |
R22/R404A |
Design standard ambient temperature (℃) |
30 |
30 |
30 |
Design standard water temperature (℃) |
20 |
20 |
20 |
Ice-making water consumption (m3/h) |
0.126 |
0.21 |
0.42 |
Water supply pipe size |
1" |
1" |
11/2" |
Ice machine weight (kg) |
1280 |
1600 |
2750 |
Ice maker size (mm) |
1500*1300*2100 |
1800*1400*2450 |
2100*1500*3100 |
Outdoor cooling tower size (mm) |
φ1165*1645 |
φ1385*2150 |
φ1880*2120 |
Cooling tower operating weight (kg) |
290 |
500 |
975 |
Model Parameter category |
IT15T-R2/4W |
IT20T-R2/4W |
IT25T-R2/4W |
Power Specifications |
3P/380/50HZ |
3P/380/50HZ |
3P/380/50HZ |
Compressor model |
CSH7563-70Y/RC2-230B |
CSH8573-90/RC2-300B |
CSH8553-110/RC2-340B |
Standard ice production |
15t/24h |
20t/24h |
30t/24h |
Standard pipe diameter |
φ29 |
φ29 |
φ29 |
Cooling capacity (kW) |
120 |
153 |
180 |
Evaporation temperature (℃) |
-15 |
-15 |
-15 |
Condensing temperature (℃) |
40 |
38 |
40 |
Total input power (kW) |
55 |
66.8 |
78 |
Compressor input power (kW) |
45.7 |
56 |
65.6 |
Compressor input power (kW) |
1.5 |
1.5 |
1.5 |
Input power of ice pump (kW) |
2.2 |
2.2 |
2.2 |
Cooling water pump |
YLGB100-20 |
YLGB100-2OK |
YLGB100-24 |
Condenser water pump input power (kW) |
4 |
5.5 |
5.5 |
Cooling tower model |
CT-80 |
CT-100 |
CT-125 |
Cooling tower fan input power (kW) |
1.5 |
1.5 |
2.25 |
Water pressure requirements |
0.1Mpa-0.5Mpa |
0.1Mpa-0.5Mpa |
0.1Mpa-0.5Mpa |
The refrigerant |
R22/R404A |
R22/R404A |
R22/R404A |
Design standard ambient temperature (℃) |
30 |
30 |
30 |
Design standard water temperature (℃) |
20 |
20 |
20 |
Ice-making water consumption (m3/h) |
0.63 |
0.84 |
1.05 |
Water supply pipe size |
2" |
2" |
2" |
Ice machine weight (kg) |
4200 |
4800 |
5800 |
Ice maker size (mm) |
2300*1900*3650 |
2300*1900*4100 |
2300*1900*4500 |
Outdoor cooling tower size (mm) |
φ2100*2510 |
1500*1350*3200 |
1730*1520*3400 |
Cooling tower operating weight (kg) |
1280 |
φ2100*2510 |
Φ2900*2875 |